H O T F I X 1 F O R A B B A / 2 2 . 3 0 G Installationprerequisite : ABBA/2 Software 2.30G Related ticket : ---- Contents of the floppy : PLWMULTI.IRD Installation : - Reset the Rho Controller, no power on, only mainswitch on - Upload original Files from Version 2.30G to your Harddisk (Backup for safety) - Download the file to the Rho Controller - Reset the Rho Controller Description : Changes in value NEW G_BGL Functions Parameter name"D_Z_CL_3" is changed to "D_Z_PUT_2". Z_Offset on the push action. Works only, if the G_CLOSE ist set to 1 Parameter "G_BGL" has an advantage function. Now he hat 2 functions. Bit 0..1 works as the old G_BGL. Bit 2..3 is for set the gripper pressure if the cartridge will be pushed into the Unit. valence: 128 64 32 16 8 4 2 1 G_BGL : 0 0 0 0 0 0 0 0 ----- ----- | | |00 no bow pressure on release cartr. | +--|01 full bow pressure on release cart. | |10 half bow pressure on release cart. | =========================================== | |00 bow pressure is as the old programm +-------| G_Bgl was used for both actions before |01 full bow pressure on push |10 no bow pressure on push EXAPLE: half pressure on release the cartride and full pressure on push the cartridge. 00000110 binaer = 6 Decimal. Set the G_BGL Value to 6. EMASS-Grau Storage Systems, 09.12.98