Here are notes by brand name that were too specific to a certain terminal to be put elsewhere in this HOWTO. If you have some info to contribute on a certain terminal that is not covered elsewhere, it could go here. Various models and brands often have much in common which only need be written about in one place. It would be nice to have for each terminal model, a large set of links linking to the documentation relevant to that model (including escape codes). There are so many models of terminals that such a task would be quite onerous and I, David Lawyer (as of 1998), have no intention of attempting this. If terminal manufacturers would only make their manuals available on the net, then all this might not be needed.
CIT terminals were made in Japan in the 1980's for CIE Terminals. They ceased to be imported in the late 1980's. The company, CIE, still makes CItoh printers (in 1997) but has no parts for its abandoned terminals. Ernie at (714) 453-9555 in Irvine CA sells (in 1997) some parts for models 224, 326, etc. but has nothing for the 80 and 101. (The document you are now reading was written mostly on the 101e.)
To save the Set-Up parameters press ^S when in Set-Up mode. cit80: Contrast: knob on rear of terminal, cit101e: Brightness: use up/down arrow keys in Set-Up mode.
Don't confuse IBM terminals with IBM PC monitors. Many IBM terminals don't use ASCII but instead use an 8-bit EBCDIC code. It's claimed that in EBCDIC the bit order of transmission is reversed from normal with the high-order bit going first. The IBM mainframe communication standards are a type of synchronous communication in block mode (sends large packets of characters). Two standards are "BISYNC" and "SNA" (which includes networking standards). Many of their terminals connect with coax cable (RG62A/U) and naive persons may think the "BNC" connecter on the terminal is for ethernet (but it's not).
While this IBM system is actually more efficient than what is normally used in Linux, terminals meeting this IBM standard will not currently work with Linux. However, some IBM terminals are asynchronous ASCII terminals and should work with Linux on PC's. The numbers 31xx may work with the exception that 317x and 319x are not ASCII terminals. Before getting an IBM terminal, make sure there is a termcap (terminfo) for it. If their isn't, it likely will not work with Linux. Even if there is a terminfo, it may not work. For example, there is a termcap for 327x but the 3270 is an EBCDIC synchronous terminal.
The 3270 series includes the 3278 (late 1970's), 3279 with color and graphics, and the 3274 terminal controller (something like the 3174). They may be used for both BISYNC and SNA. The 3290 has a split screen (splits into quarters).
The synchronous IBM terminals don't connect directly to the IBM mainframe, but connect to a "terminal controller" (sometimes called "cluster controller" or "communication controller"). Some of these controllers can convert a synchronous signal to asynchronous so that in this case a synchronous terminal could indirectly connect to a Unix-like host computer via its serial port. But there is still a major problem and that is block transmission. See section Block Mode.
It's claimed that the Aux port is DCE and uses a straight-thru cable.
These are antiques and represent the oldest terminals. They are like remotely controlled typewriters but are large and noisy. Made by the Teletype Corp., the first models were made in the 1920's and predate the computer by over 30 years. Early models used electro-mechanical relays and rotating distributors instead of electronics. Their Baudot code was only 5-bits per character as compared to 7-bit ASCII. See the book "Small Computer Systems Handbook" by Sol Libes, Hayden Books, 1978: pp. 138-141 ("Teletypes").
Digital Equipment Corporation made the famous VT series of terminals including the commonly emulated VT100. In 1995 they sold their terminal business to SunRiver which is now named Boundless Technologies. More information is available at Shuford's Website Information on current products is available from the Boundless website. See Terminal Info on the Internet.
VT220: Some have a BNC connector for video output (not for input). Sometimes people erroneously think this is for an ethernet connection.
VT520: Supports full DTR/DSR flow control.
Wyse has some FAQ's for terminal numbers under 100 (such as WY60). See http://www.wyse.com/service/faq/wysetter.htm For the specs on more recent terminals see See http://www.wyse.com/terminal/.
Display adjustments (must remove cover): Brightness VR202, Height VR302, Width VR101 (also affects height).
Here is the setup Menus of the Wyse99GT (late 1980's). Note that TERM means "termination" (character) and not "terminal".
WYSE 99-GT Terminal Set-Up as used at the University of CA, Irvine by David Lawyer, April 1990 F1 DISP: COLUMNS=80 LINES=24 CELL SIZE=10 X 13 STATUS LINE=STANDARD BACKGROUND=DARK SCROLL SPEED=JUMP SCREEN SAVER=OFF CURSOR=BLINK BLOCK DISPLAY CURSOR=ON ATTRIBUTE=CHAR END OF LINE WRAP=ON AUTO SCROLL=ON ---------------------------------------------------------------------------- F2 GENERAL: PERSONALITY=VT 100 ENHANCE=ON FONT LOAD=OFF COMM MODE=FULL DUPLEX RCVD CR=CR SEND ACK=ON RESTORE TABS=ON ANSWERBACK MODE=OFF ANSWERBACK CONCEAL=OFF WIDTH CHANGE CLEAR=OFF MONITOR=OFF TEST=OFF ---------------------------------------------------------------------------- F3 KEYBRD: KEYCLICK=OFF KEYLOCK=CAPS KEY REPEAT=ON RETURN=CR ENTER=CR FUNCT KEY=HOLD XMT LIMIT=NONE FKEY XMT LIMIT=NONE BREAK=170MS LANGUAGE=US MARGIN BELL=OFF PRINTER RCV=OFF ---------------------------------------------------------------------------- F4 COMM: DATA/PRINTER=AUX/MODEM MDM RCV BAUD RATE=9600 MDM XMT BAUD RATE=9600 MDM DATA/STOP BITS=8/1 MDM RCV HNDSHAKE=NONE MDM XMT HNDSHAKE=NONE MDM PARITY=NONE AUX BAUD RATE=9600 AUX DATA/STOP BITS=8/1 AUX RCV HNDSHAKE=NONE AUX XMT HNDSHAKE=NONE AUX PARITY=NONE (There is a main port (Modem=MDM) and an Auxiliary Port (AUX) ---------------------------------------------------------------------------- F5 MISC 1: WARNING BELL=ON FKEY LOCK=OFF FEATURE LOCK=ON KEYPAD=NUMERIC DEL=DEL/CAN XFER TERM=EOS CURSOR KEYS=NORMAL MARGIN CTRL=0 DEL FOR LOW Y=ON GIN TERM=CR CHAR MODE=MULTINATIONAL ---------------------------------------------------------------------------- F6 MISC 2: LOCAL=OFF SEND=ALL PRINT=NATIONAL PORT=EIA DATA SEND AREA=SCREEN PRINT AREA=SCREEN DISCONNECT=60 MSEC SEND TERM=NONE PRINT TERM=NONE PRINT MODE=NORMAL VT100 ID=VT100 POUND=US ---------------------------------------------------------------------------- F7 TABS: You should see several "T" characters spaced 8 dots apart. If you don't, hit backspace. F8 F/KEYS: Normally you will see no definitions for the Function Keys here (unless someone has set them up and saved them). This means that they will normally generate their default settings (not displayed here). <ctrl><F5> shows the "user defined definition" of the F5 key, etc. F9 A/BACK: Normally not defined: ANSWERBACK = F10 EXIT: Selecting "DEFAULT ALL" will make the factory default settings the default.
HINTS on use of WY-99GT User's Guide: Note that much that is missing from this Guide may be found in the WY-99GT Programmer's Guide. The VT100 emulation (personality) is known as ANSI and uses ANSI key codes per p. A-10+ even though the keyboard may be ASCII. A sub-heading on p. A-13 "ASCII Keyboard" also pertains to VT100 because it has an "ANSI KEY ..." super-heading a few pages previously. But not all ASCII keyboard headings pertain to VT100 since they may fall under a non-ANSI personality super-heading which may found be a few pages previously. Appendix H is the "ANSI Command Guide" except for the VT52 (ANSI) personality which is found in Appendix G.
When exiting set-up using F12, hitting space changes "no" to "yes" to save the set-up. The sentence to the left of this no/yes is about "vertical alignment" and has nothing to do with this no/yes for saving the set-up (confusing menu design).
END OF Text-Terminal-HOWTO